Wall Assembly & Condensation (Glaser)

U-value, temperature and vapour-pressure profile through a wall build-up, and where interstitial or surface condensation can form.

How it works — Wall Assembly & Condensation (Glaser)

Ti To pv

Inputs

Ti
Indoor temperature (°C)
To
Outdoor temperature (°C)
φ
Indoor relative humidity (%)

Formula

  • U = 1/(R_si + Σd/λ + R_se)
  • p_v > p_sat → condensation

Results

U
U-value
pv
Condensation risk
Conditions
Layers (inside → outside)
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

U = 1/(R_si + Σd/λ + R_se) · s_d = μ·d · condensation where p_v > p_sat

Try removing the vapour barrier or swapping the insulation to see how the risk moves. The Glaser method is a steady-state screening check.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Steady-state, one-dimensional heat and vapour flow (ISO 13788 Glaser method).
  • Typical conductivities and vapour resistance factors; R_si = 0.13 and R_se = 0.04 m²·K/W.
  • No moisture storage, liquid transport or air leakage.

References

  • ISO 13788: Hygrothermal performance of building components — Internal surface temperature and interstitial condensation
  • ISO 6946: Thermal resistance and thermal transmittance
  • ISO 10456: Declared and design thermal values

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.