Level 3 — Standard / code based

Seismic Base Shear (Equivalent Lateral Force)

Approximate period, seismic response coefficient with its limits, base shear, vertical force distribution and the design response spectrum.

How it works — Seismic Base Shear (Equivalent Lateral Force)

V W, T

Inputs

W
Effective seismic weight W (kN)
T
Analysed period (optional) (s)

Formula

  • T_a = C_th_n^x
  • C_s = S_DS/(R/I_e) ≤ S_D1/(T·R/I_e)
  • V = C_s·W
  • F_x = C_vx·V

Results

V
Seismic base shear V
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

T_a = C_th_n^x · C_s = S_DS/(R/I_e) ≤ S_D1/(T·R/I_e) · V = C_s·W · F_x = C_vx·V

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 3 — Standard / code based

Follows the method of the named design standard within the stated scope; it does not check every provision of that standard.

Design standard / method: ASCE 7-16 §12.8 equivalent lateral force procedure

Assumptions

  • Equal storey heights and weights for the vertical distribution.
  • S_DS and S_D1 are the site design values you enter.

References

  • ASCE/SEI 7-16: Minimum Design Loads for Buildings and Other Structures

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in

or with email

Forgot password?