Level 1 — Basic calculation
Battery Pack Builder (Series/Parallel, C-Rate, Runtime)
Pack voltage, capacity, energy, current and power limits of a series–parallel battery pack from cell data, with the C-rate and runtime at a load.
How it works — Battery Pack Builder (Series/Parallel, C-Rate, Runtime)
Inputs
- Ns
- Cells in series
- Np
- Cells in parallel
- V
- Cell nominal voltage (V)
- Ah
- Cell capacity (Ah)
- C-rate
- Maximum continuous discharge C-rate (C)
Formula
- V = N_s·V_cell
- C = N_p·C_cell
- E = V·C
- I_max = C-rate·C
- t = E·min(SoC, DoD)/P
Results
- V
- Pack nominal voltage
- Ah
- Pack capacity
- kWh
- Pack energy
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
V = N_s·V_cell · C = N_p·C_cell · E = V·C · I_max = C-rate·C · t = E·min(SoC, DoD)/P
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Calculation level & design standard
Level 1 — Basic calculation
A direct engineering equation.
Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.
Assumptions
- Generic battery model: no chemistry-specific behaviour is assumed beyond the cell data you enter.
- Constant voltage at the nominal value; Peukert effect, temperature and ageing ignored.
References
- D. Linden, T. B. Reddy, Linden's Handbook of Batteries
- IEC 62660-1: Secondary lithium-ion cells for electric vehicles
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Electrical Engineering tools
- Electrical Engineering Battery Runtime How long a battery bank can power a load, allowing for depth of discharge and inverter efficiency. Open tool
- Electrical Engineering Off-Grid Solar & Battery System Sizing Battery bank, PV array, inverter and charge controller for an off-grid system from the daily energy, days of autonomy, depth of discharge and sun hours. Open tool
- Electrical Engineering EV Charging Time, Power & Site Load Charging power, energy and time for Level 1, Level 2 and DC fast charging, and the site load of several chargers with a diversity factor. Open tool
- Electrical Engineering Solar PV String & Array Sizing Modules per string and parallel strings from temperature-corrected module voltages and the inverter's MPPT window, array power, I–V curve and an annual energy estimate. Open tool