Level 1 — Basic calculation

Fiber-Optic Link: NA, V-Number, Power Budget & Dispersion

Numerical aperture, acceptance angle, V-number and mode count of a step-index fiber, the optical power budget and margin, and the dispersion-limited bit rate.

How it works — Fiber-Optic Link: NA, V-Number, Power Budget & Dispersion

n2 n1 θ αℓ, D·Δλ·ℓ

Inputs

n1
Core index n₁
n2
Cladding index n₂
αℓ
Attenuation (dB/km)

Formula

  • NA = √(n₁² − n₂²)
  • V = 2πa·NA/λ (single-mode if V < 2.405)
  • P_r = P_t − αℓ − ΣL
  • Δt = D·Δλ·ℓ

Results

θ
Acceptance half-angle
Pr
Received power
Fiber
Link
Optics
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

NA = √(n₁² − n₂²) · V = 2πa·NA/λ (single-mode if V < 2.405) · P_r = P_t − αℓ − ΣL · Δt = D·Δλ·ℓ

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 1 — Basic calculation

A direct engineering equation.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Step-index fiber; mode count ≈ V²/2 for multimode.
  • Bit-rate estimate B ≈ 1/(4Δt) for NRZ.

References

  • G. Keiser, Optical Fiber Communications
  • ITU-T G.652: Characteristics of a single-mode optical fibre

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.