Level 1 — Basic calculation
Isentropic Flow Calculator (Mach Number Relations)
Static-to-stagnation temperature, pressure and density ratios and the area ratio A/A* for any Mach number and gas, with the A/A* curve.
How it works — Isentropic Flow Calculator (Mach Number Relations)
Inputs
- M
- Mach number M
- γ
- Specific heat ratio γ
Formula
- T/T₀ = (1 + (γ−1)M²/2)⁻¹
- A/A* = (1/M)[…]^((γ+1)/(2(γ−1)))
Results
- T/T₀
- Temperature ratio
- p/p₀
- Pressure ratio
- A/A*
- Area ratio
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
\frac{T}{T_0} = \left(1 + \frac{\gamma - 1}{2} M^2\right)^{-1}\frac{p}{p_0} = \left(1 + \frac{\gamma - 1}{2} M^2\right)^{-\frac{\gamma}{\gamma - 1}}\frac{\rho}{\rho_0} = \left(1 + \frac{\gamma - 1}{2} M^2\right)^{-\frac{1}{\gamma - 1}}\frac{A}{A^*} = \frac{1}{M}\left[\frac{2}{\gamma + 1}\left(1 + \frac{\gamma - 1}{2} M^2\right)\right]^{\frac{\gamma + 1}{2(\gamma - 1)}}M > 1:\quad \mu = \arcsin\frac{1}{M},\qquad \nu = \sqrt{\frac{\gamma+1}{\gamma-1}}\,\arctan\sqrt{\frac{\gamma-1}{\gamma+1}(M^2-1)} - \arctan\sqrt{M^2-1}LaTeX source and plain-text formula
\frac{T}{T_0} = \left(1 + \frac{\gamma - 1}{2} M^2\right)^{-1}
\frac{p}{p_0} = \left(1 + \frac{\gamma - 1}{2} M^2\right)^{-\frac{\gamma}{\gamma - 1}}
\frac{\rho}{\rho_0} = \left(1 + \frac{\gamma - 1}{2} M^2\right)^{-\frac{1}{\gamma - 1}}
\frac{A}{A^*} = \frac{1}{M}\left[\frac{2}{\gamma + 1}\left(1 + \frac{\gamma - 1}{2} M^2\right)\right]^{\frac{\gamma + 1}{2(\gamma - 1)}}
M > 1:\quad \mu = \arcsin\frac{1}{M},\qquad \nu = \sqrt{\frac{\gamma+1}{\gamma-1}}\,\arctan\sqrt{\frac{\gamma-1}{\gamma+1}(M^2-1)} - \arctan\sqrt{M^2-1}
T/T₀ = (1 + (γ−1)/2·M²)⁻¹; p/p₀ = (…)^(−γ/(γ−1)); ρ/ρ₀ = (…)^(−1/(γ−1)); A/A* = (1/M)[(2/(γ+1))(1 + (γ−1)/2·M²)]^((γ+1)/(2(γ−1)))
Formulas are evaluated in SI units; inputs and results are converted.
Area ratio A/A* against Mach number
Subsonic flow accelerates in a converging duct and supersonic flow in a diverging one; the throat (A/A* = 1) is where M = 1.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Calculation level & design standard
Level 1 — Basic calculation
A direct engineering equation.
Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.
Assumptions
- Steady, one-dimensional, isentropic ideal gas flow.
- Calorically perfect gas: constant specific heats and constant γ.
- Stagnation (total) conditions are those of the gas brought adiabatically and reversibly to rest; no shocks.
References
- NACA Report 1135, Equations, Tables, and Charts for Compressible Flow (Ames Research Staff, 1953)
- J. D. Anderson, Modern Compressible Flow, 3rd ed., McGraw-Hill
- NASA Glenn Research Center, Beginner's Guide to Aeronautics (public domain)
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Aerodynamics Lab tools
- Aerodynamics Lab Mach Number Lab (Speed of Sound, Stagnation Conditions) Speed of sound, Mach number and flow regime at an altitude, stagnation temperature and pressure, incompressible and compressible dynamic pressure and the Mach cone. Open tool
- Aerodynamics Lab Normal Shock Wave Relations Downstream Mach number and the static pressure, temperature, density and total-pressure ratios across a normal shock, with the curves against upstream Mach number. Open tool
- Aerodynamics Lab Oblique Shock (θ–β–M Relation) Wave angle, downstream Mach number and pressure, temperature and density ratios of an attached oblique shock on a wedge or ramp, with the θ–β–M diagram and the detachment limit. Open tool