Overhang & Shading Designer
Depth of a horizontal overhang that fully shades a window over chosen hours and date, and how much it still shades on a second date.
How it works — Overhang & Shading Designer
Inputs
- H
- Window height (ft)
- G
- Gap from window head to overhang (ft)
- φ
- Latitude (°)
Formula
- tan Ω = tan α / cos γ
- P = (H + G) / tan Ω
Results
- P
- Required overhang depth
- Ω
- Critical profile angle
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
tan Ω = tan α / cos(γ_sun − γ_facade) · P = (H + G) / tan Ω
Formulas are evaluated in SI units; inputs and results are converted.
In the southern hemisphere swap the dates (shade in December, admit in June) and face the window north.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Assumptions
- Infinitely wide overhang (no side shading); solar time, not clock time.
- Solar declination from Cooper's equation (±0.5°); no refraction.
References
- V. Olgyay, Design with Climate
- ASHRAE Handbook — Fundamentals, ch. 14–15 (solar angles)
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Architectural tools
- Architectural Shadow Cast & Sun Path Simulator Interactive 3D sun-path and shadow study: see where a building's shadow falls at any time of day on the solstices and equinoxes. Open tool
- Architectural Stair Calculator Riser count and height, tread run, stair angle and the 2R + T comfort rule from the total floor-to-floor rise. Open tool
- Architectural Roof Pitch Calculator Roof angle, pitch in 12, percent slope and rafter length from rise and run. Open tool
- Architectural Wall Area & Paint Calculator Paintable wall area and litres of paint for a rectangular room, net of doors and windows. Open tool