Room Acoustics: RT60 (Sabine & Eyring)

Reverberation time of a room in octave bands from its size and finishes, compared with targets for classrooms, offices, theatres and more.

How it works — Room Acoustics: RT60 (Sabine & Eyring)

L H V, α

Inputs

L
Length (m)
H
Height (m)
α
Wall finish

Formula

  • T = 0.161·V / A
  • A = Σ S·α

Results

T60
Reverberation time RT60 (500–1000 Hz, Sabine)
V
Room volume
Room
Finishes
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

T = 0.161·V / A (Sabine) · T = 0.161·V / [−S·ln(1 − ᾱ)] (Eyring)

Absorption coefficients are typical values; use manufacturer data for specific products.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Diffuse sound field; absorption evenly distributed.
  • Air absorption at 2 and 4 kHz for 20 °C and 50 % RH.

References

  • L. L. Beranek, Acoustics
  • M. D. Egan, Architectural Acoustics
  • ANSI/ASA S12.60 (classrooms)

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in

or with email

Forgot password?