Site & Building Envelope Designer

From site size and setbacks to footprint, floors, height, gross and net floor area, FAR, lot coverage and a unit estimate, with a site plan.

How it works — Site & Building Envelope Designer

W D sf ss GFA

Inputs

W
Site width (frontage) (ft)
D
Site depth (ft)
sf
Front setback (ft)
ss
Side setbacks (each) (ft)
FAR
Maximum FAR (floor area ratio)

Formula

  • GFA = min(A × n, FAR × site)
  • coverage = A / site

Results

GFA
Achievable gross floor area
n
Floors
A
Building footprint
Site
Setbacks
Zoning limits
Building
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

GFA = min(footprint × floors, FAR × site) · coverage = footprint / site

Formulas are evaluated in SI units; inputs and results are converted.

Preliminary check only: requirements vary by jurisdiction and building classification; confirm with the governing code and authority.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Rectangular site with uniform setbacks; a rectangular footprint on every floor.
  • No step-backs, angular planes, parking or amenity requirements.

References

  • Local zoning by-law or development code
  • RIBA / IPMS measurement standards for GFA and NIA

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.