Rooftop Solar PV Yield
System size, annual energy, specific yield, savings and payback of a rooftop PV array from roof area and peak sun hours.
How it works — Rooftop Solar PV Yield
Inputs
- A
- Roof area (ft²)
- PSH
- Peak sun hours per day (h)
- PR
- Performance ratio (%)
Formula
- E = P × PSH × 365 × PR
Results
- kWp
- System size
- E
- Annual energy yield
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
P = A·u·p · E = P·PSH·365·PR
Formulas are evaluated in SI units; inputs and results are converted.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Assumptions
- Constant performance ratio; no shading, degradation or battery storage.
References
- NREL PVWatts methodology
- IEC 61724: Photovoltaic system performance
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Architectural tools
- Architectural Shadow Cast & Sun Path Simulator Interactive 3D sun-path and shadow study: see where a building's shadow falls at any time of day on the solstices and equinoxes. Open tool
- Architectural Stair Calculator Riser count and height, tread run, stair angle and the 2R + T comfort rule from the total floor-to-floor rise. Open tool
- Architectural Roof Pitch Calculator Roof angle, pitch in 12, percent slope and rafter length from rise and run. Open tool
- Architectural Wall Area & Paint Calculator Paintable wall area and litres of paint for a rectangular room, net of doors and windows. Open tool