Window & Daylight Calculator

Window-to-wall and window-to-floor ratios, average daylight factor, daylit depth and the room-depth rule for a side-lit room.

How it works — Window & Daylight Calculator

L hw ADF θ

Inputs

L
Room depth (m)
hw
Window height (m)
θ
Visible sky angle θ (°)
T
Glazing light transmittance

Formula

  • ADF = T·A_w·θ·M / A(1 − R²)
  • WWR = A_w / A_wall

Results

ADF
Average daylight factor
WWR
Window-to-wall ratio
WFR
Window-to-floor ratio
Room

Light-coloured room ≈ 0.5–0.6

Window

Clear double glazing ≈ 0.7–0.8

90° when unobstructed

Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

ADF = T·A_w·θ·M / [A·(1 − R²)] · WWR = A_w / A_wall

An average daylight factor of 2 % or more usually means a room looks daylit; 5 % is well daylit.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Side-lit room under an overcast sky; one window wall.
  • Uniform average reflectance of room surfaces.

References

  • P. Littlefair, BRE BR 209: Site layout planning for daylight and sunlight
  • CIBSE LG10: Daylighting — a guide for designers

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.