Level 2 — Engineering approximation

Strip Footing Bearing Capacity

Ultimate and allowable soil bearing capacity of a strip footing using the general bearing capacity equation.

How it works — Strip Footing Bearing Capacity

Df B qult c′ φ′ γ

Inputs

B
Footing width B (ft)
Df
Footing depth Df (ft)
c′
Cohesion c′ (psf)
φ′
Friction angle φ′ (°)
γ
Soil unit weight γ (pcf)
FS
Factor of safety

Formula

  • q_ult = c′Nc + γDf·Nq + ½γB·Nγ
  • q_all = q_ult / FS

Results

qult
Ultimate bearing capacity
qall
Allowable bearing pressure
qall·B
Allowable line load
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

q_ult = c′Nc + γDf·Nq + ½γB·Nγ · q_all = q_ult / FS

Formulas are evaluated in SI units; inputs and results are converted.

Factors: Nq = e^(π tanφ)·tan²(45°+φ/2), Nc = (Nq−1)cotφ, Nγ = 2(Nq+1)tanφ (Vesić). No shape, depth or inclination factors.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 2 — Engineering approximation

A preliminary engineering model with the simplifications listed under Assumptions.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Long strip footing on homogeneous soil; general shear failure.
  • Vertical, concentric load; level ground; groundwater below the failure zone.
  • No shape, depth or inclination factors.

References

  • B. M. Das, Principles of Foundation Engineering
  • A. S. Vesić (1973), Analysis of ultimate loads of shallow foundations, J. Soil Mech. Found. Div. ASCE

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in

or with email

Forgot password?