Level 1 — Basic calculation

Mixing & Mass Balance (Dilution, Decay)

Concentration after two streams mix, mass load, dilution ratio and first-order decay with travel time.

How it works — Mixing & Mass Balance (Dilution, Decay)

Q1, C1 Q2, C2 C

Inputs

Q1
Upstream flow Q₁ (m³/s)
C1
Upstream concentration C₁ (mg/L)
Q2
Discharge flow Q₂ (m³/s)
C2
Discharge concentration C₂ (mg/L)

Formula

  • C = (Q₁C₁ + Q₂C₂)/(Q₁ + Q₂)
  • C_t = C·e^(−kt)

Results

C
Mixed concentration
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

C = (Q₁C₁ + Q₂C₂)/(Q₁ + Q₂) · C_t = C·e^(−kt)

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 1 — Basic calculation

A direct engineering equation.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Complete and instantaneous mixing; first-order decay; conservative flows.

References

  • M. L. Davis, D. A. Cornwell, Introduction to Environmental Engineering

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.