Level 3 — Standard / code based

One-Way Concrete Slab (ACI 318)

Minimum thickness, factored load, moment, required and shrinkage steel and bar spacing per metre width of a one-way slab.

How it works — One-Way Concrete Slab (ACI 318)

wu ℓ h

Inputs

ℓ
Clear span ℓ (m)
h
Thickness (blank = minimum) (mm)
wu
Live load (kPa)

Formula

  • h_min = ℓ/k·(0.4 + f_y/700)
  • w_u = 1.2D + 1.6L
  • M_u = C·w_u·ℓ²
  • A_s,min = 0.0018·b·h

Results

M
Design moment per metre
s
Bar spacing
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

h_min = ℓ/k·(0.4 + f_y/700) · w_u = 1.2D + 1.6L · M_u = C·w_u·ℓ² · A_s,min = 0.0018·b·h

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 3 — Standard / code based

Follows the method of the named design standard within the stated scope; it does not check every provision of that standard.

Design standard / method: ACI 318-19 (SI) — rectangular sections, flexure and one-way shear only; other provisions not checked

Assumptions

  • Approximate moment coefficients (ℓ²/8, /10, /11, /2) instead of the ACI coefficient tables or an analysis.
  • Load combination 1.2D + 1.6L only; normal-weight concrete; shear and deflection not checked.

References

  • ACI 318-19: Building Code Requirements for Structural Concrete (SI)

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in

or with email

Forgot password?