Level 1 — Basic calculation

Open-Channel & Partially Full Pipe Flow (Manning)

Discharge for a depth or the normal depth for a discharge in rectangular, trapezoidal, triangular and circular channels, with critical depth, Froude number and a rating curve.

How it works — Open-Channel & Partially Full Pipe Flow (Manning)

b y z Q, n, S

Inputs

b
Bottom width b (ft)
z
Side slope z (H:1V)
n
Manning's n
S
Bed slope S (m/m)

Formula

  • Q = (1/n)·A·R^(2/3)·S^(1/2)
  • Fr = V/√(gD_h)
  • Q²T/(gA³) = 1 (critical)

Results

y
Flow depth (normal depth)
Q
Discharge Q
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

Q = (1/n)·A·R^(2/3)·S^(1/2) · Fr = V/√(gD_h) · Q²T/(gA³) = 1 (critical)

Formulas are evaluated in SI units; inputs and results are converted.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 1 — Basic calculation

A direct engineering equation.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Steady, uniform flow; Manning's n constant with depth.

References

  • V. T. Chow, Open-Channel Hydraulics

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.