Level 2 — Engineering approximation

Pile Axial Capacity (α & β Methods)

Shaft friction and end bearing of a single driven pile in layered clay and sand, allowable capacity and pile-group efficiency.

How it works — Pile Axial Capacity (α & β Methods)

Qb Qs clay: α·c_u sand: β·σ′_v

Inputs

D
Pile diameter (ft)
c_u, φ
Soil layers (top down)

Formula

  • Q_ult = Σf_s·πD·ΔL + q_b·A
  • clay f_s = αc_u, sand f_s = βσ′_v
  • Q_all = Q_ult/FS

Results

Qs
Shaft resistance
Qb
End bearing

One layer per line: thickness (m), clay or sand, unit weight (kN/m³), c_u (kPa) for clay or φ (°) for sand. The pile tip is at the bottom of the last layer.

Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

Q_ult = Σf_s·πD·ΔL + q_b·A · clay f_s = αc_u, sand f_s = βσ′_v · Q_all = Q_ult/FS

Formulas are evaluated in SI units; inputs and results are converted.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 2 — Engineering approximation

A preliminary engineering model with the simplifications listed under Assumptions.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Driven pile; API α for clay, β = (1 − sinφ)tan(0.75φ) for sand; tip resistance in the last layer.
  • Group efficiency by Converse–Labarre (indicative, mainly for friction piles in clay).

References

  • B. M. Das, Principles of Foundation Engineering
  • API RP 2A-WSD: Planning, designing and constructing fixed offshore platforms (pile capacity)

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.