Level 2 — Engineering approximation

Cantilever Retaining Wall Stability

Sliding, overturning and bearing checks, resultant eccentricity and base pressures of a cantilever retaining wall with Rankine active pressure and surcharge.

How it works — Cantilever Retaining Wall Stability

Pa q W B

Inputs

B
Base width (ft)
q
Surcharge (psf)

Formula

  • FS_sliding = (ΣV·tanδ + c_aB + P_p)/P_a ≥ 1.5
  • FS_overturning = ΣM_R/ΣM_O ≥ 2.0
  • q = ΣV/B(1 ± 6e/B)

Results

Pa
Active thrust (per metre)
W
Total vertical load (per metre)
Geometry
Soil
Base
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

FS_sliding = (ΣV·tanδ + c_aB + P_p)/P_a ≥ 1.5 · FS_overturning = ΣM_R/ΣM_O ≥ 2.0 · q = ΣV/B(1 ± 6e/B)

Formulas are evaluated in SI units; inputs and results are converted.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 2 — Engineering approximation

A preliminary engineering model with the simplifications listed under Assumptions.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Rankine active pressure on a vertical plane through the heel; level backfill; no water pressure.
  • Usual minimum factors of safety 1.5 (sliding) and 2.0 (overturning); structural design of the stem and base not included.

References

  • B. M. Das, Principles of Foundation Engineering
  • FHWA-NHI-10-024: Design of mechanically stabilized earth walls and reinforced soil slopes (stability concepts)

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in