Level 1 — Basic calculation

Tank Detention Time & Loading Rates

Hydraulic detention time, surface overflow rate, horizontal velocity and organic loading of a rectangular treatment tank.

How it works — Tank Detention Time & Loading Rates

Q V = L·W·H t = V/Q

Inputs

Q
Flow (m³/d)
L
Length (m)
W
Width (m)
H
Water depth (m)

Formula

  • t = V/Q
  • SOR = Q/A
  • L = Q·C

Results

t
Hydraulic detention time
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

t = V/Q · SOR = Q/A · L = Q·C

Formulas are evaluated in SI units; inputs and results are converted.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 1 — Basic calculation

A direct engineering equation.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Plug-flow geometry for the horizontal velocity; average flow.

References

  • Metcalf & Eddy, Wastewater Engineering: Treatment and Resource Recovery

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.