Level 1 — Basic calculation

DC Motor Speed, Torque & PWM Drive

Steady-state speed, current, back-EMF, power and efficiency of a permanent-magnet or separately excited DC motor driven by a PWM duty cycle.

How it works — DC Motor Speed, Torque & PWM Drive

M + V T, ω D

Inputs

V
Supply voltage (V)
D
PWM duty cycle (%)
Ra
Armature resistance R_a (Ω)
k
Motor constant k (V·s/rad = N·m/A)
T
Load torque (N·m)

Formula

  • V = E + I·R_a
  • E = k·ω
  • T = k·I
  • P = T·ω
  • V = D·V_s

Results

ω
Speed
I
Armature current
η
Efficiency
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

V = E + I·R_a · E = k·ω · T = k·I · P = T·ω · V = D·V_s

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 1 — Basic calculation

A direct engineering equation.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Constant field flux (permanent magnet or separately excited); brush drop and inductance neglected in steady state.
  • A PWM drive is represented by its average voltage (continuous conduction).

References

  • S. J. Chapman, Electric Machinery Fundamentals
  • N. Mohan, Electric Drives: An Integrative Approach

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.