Level 1 — Basic calculation
Fresnel Zone & Path Clearance
First Fresnel zone radius, earth bulge, clearance over an obstacle and the extra antenna height needed, with the path profile.
How it works — Fresnel Zone & Path Clearance
Inputs
- d1
- Obstacle distance from antenna 1 (km)
- hobs
- Obstacle height (ft)
Formula
- r₁ = √(λd₁d₂/d)
- h_b = d₁d₂/(2kR_e)
- clearance = h_LOS − h_b − h_obs ≥ 0.6·r₁
Results
- r1
- First Fresnel zone radius at the obstacle
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
r₁ = √(λd₁d₂/d) · h_b = d₁d₂/(2kR_e) · clearance = h_LOS − h_b − h_obs ≥ 0.6·r₁
Formulas are evaluated in SI units; inputs and results are converted.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Calculation level & design standard
Level 1 — Basic calculation
A direct engineering equation.
Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.
Assumptions
- Smooth spherical earth with an effective radius kR_e; a single knife-edge obstacle.
References
- ITU-R P.530: Propagation data for terrestrial line-of-sight systems
- ITU-R P.526: Propagation by diffraction
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Electrical Engineering tools
- Electrical Engineering RF Link Budget (FSPL, Received Power, Margin, SNR) Wavelength, free-space path loss, EIRP, received power, link margin, noise floor, SNR and the Shannon capacity of a radio link, with a level diagram. Open tool
- Electrical Engineering Antenna Calculator & Radiation Pattern Dipole and monopole lengths, gain, directivity, beamwidth, front-to-back ratio and effective aperture of a dipole, a linear array or a parabolic dish, with a polar pattern. Open tool
- Electrical Engineering Decibel Calculator (dB, dBm, dBW & Cascades) Convert between watts, dBm, dBW and power or voltage ratios, and add the gains and losses of a cascade of stages. Open tool
- Electrical Engineering Transmission Line, VSWR, Smith Chart & Matching Reflection coefficient, VSWR, return and mismatch loss, input impedance and L-network or quarter-wave matching, on an interactive Smith chart where you can move the load. Open tool