Level 4 — Numerical analysis
Transfer Function Analysis: Poles, Bode, Nyquist, Root Locus
Poles, zeros, stability, DC gain, gain and phase margins, Bode, Nyquist and root-locus plots and the step response of a transfer function, open or closed loop.
How it works — Transfer Function Analysis: Poles, Bode, Nyquist, Root Locus
Inputs
- N(s)
- Numerator coefficients (highest power first)
- D(s)
- Denominator coefficients (highest power first)
Formula
- G(s) = K·N(s)/D(s)
- T(s) = G/(1 + G)
- stable ⇔ Re(poles) < 0
- GM = −20log|G(jω₁₈₀)|, PM = 180° + ∠G(jω_c)
Results
- pi
- Poles
- GM, PM
- Phase margin (open loop)
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
G(s) = K·N(s)/D(s) · T(s) = G/(1 + G) · stable ⇔ Re(poles) < 0 · GM = −20log|G(jω₁₈₀)|, PM = 180° + ∠G(jω_c)
Formulas are evaluated in SI units; inputs and results are converted.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Calculation level & design standard
Level 4 — Numerical analysis
A numerical solver: matrix analysis, iteration or time integration.
Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.
Assumptions
- Linear time-invariant, proper rational transfer function; margins evaluated on the open loop K·G(s).
References
- K. Ogata, Modern Control Engineering
- N. S. Nise, Control Systems Engineering
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Electrical Engineering tools
- Electrical Engineering PID Controller Step Response (Closed-Loop Simulation) Simulate a PID loop on a first-order-plus-dead-time or second-order plant: step response, overshoot, rise and settling time, steady-state error, actuator limits and SIMC tuning. Open tool
- Electrical Engineering Passive Filter Design (RC, RL, RLC) & Bode Plot Cut-off or centre frequency, Q, bandwidth and gain of RC, RL and RLC low-pass, high-pass, band-pass and band-stop filters, with Bode magnitude and phase. Open tool
- Electrical Engineering ADC / DAC Resolution, Sampling & Aliasing LSB size, output code, ideal SQNR, Nyquist frequency, aliasing and data rate of an analog-to-digital converter, with a sampling chart. Open tool
- Electrical Engineering PWM Timer: Frequency, Duty Cycle & Resolution Timer TOP and compare values, actual frequency, resolution, duty step and average output of a microcontroller PWM, with the waveform. Open tool