Level 1 — Basic calculation

Transmission Line, VSWR, Smith Chart & Matching

Reflection coefficient, VSWR, return and mismatch loss, input impedance and L-network or quarter-wave matching, on an interactive Smith chart where you can move the load.

How it works — Transmission Line, VSWR, Smith Chart & Matching

Γ Z0, ℓ ZL

Inputs

Z0
Z₀ (Ω)
ZL
Load resistance R_L (Ω)
ℓ
Line length (m)

Formula

  • Γ = (Z_L − Z₀)/(Z_L + Z₀)
  • VSWR = (1 + |Γ|)/(1 − |Γ|)
  • RL = −20log|Γ|
  • Z_in = Z₀(Z_L + jZ₀tanβℓ)/(Z₀ + jZ_L tanβℓ)

Results

Γ
Reflection coefficient |Γ|
VSWR
VSWR

Interactive Smith chart

Click or drag inside the chart to move the load: R_L and X_L update and the engine recalculates Γ, VSWR, the input impedance and the matching networks.

Z_L
Γ
VSWR
Return loss
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

Γ = (Z_L − Z₀)/(Z_L + Z₀) · VSWR = (1 + |Γ|)/(1 − |Γ|) · RL = −20log|Γ| · Z_in = Z₀(Z_L + jZ₀tanβℓ)/(Z₀ + jZ_L tanβℓ)

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 1 — Basic calculation

A direct engineering equation.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Lossless line with a real characteristic impedance.
  • Lumped matching elements are ideal at the design frequency.

References

  • D. M. Pozar, Microwave Engineering
  • P. H. Smith (1939), Transmission line calculator, Electronics

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in

or with email

Forgot password?