Measurement Uncertainty (GUM & Monte Carlo)

Propagate the uncertainty of up to five inputs through any formula: sensitivity coefficients, combined and expanded uncertainty, and a Monte Carlo check.

How it works — Measurement Uncertainty (GUM & Monte Carlo)

y 2uc U = k·u

Inputs

y
Formula for y
k
Coverage factor k
a
Value of a

Formula

  • u_c² = Σ(∂y/∂x_i)²·u_i²
  • U = k·u_c

Results

uc
Combined standard uncertainty u_c
U
Expanded uncertainty U = k·u_c

Use the variables a–e, + − * / ** and sqrt, exp, ln, log10, sin, cos, tan, pi. Example: a*b/c**2

k = 2 gives about 95 % coverage

Variable a
Variable b
Variable c
Variable d
Variable e
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

u_c² = Σ (∂y/∂x_i)²·u(x_i)² · U = k·u_c

Formulas are evaluated in SI units; inputs and results are converted.

Inputs are treated as uncorrelated. For a rectangular distribution enter the half-width a; the standard uncertainty is a/√3.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Uncorrelated input quantities.
  • First-order (linear) propagation for u_c; the Monte Carlo result shows whether that is adequate.
  • Monte Carlo uses 20,000 trials with a fixed seed, so results are repeatable.

References

  • JCGM 100:2008 (GUM) — Evaluation of measurement data: Guide to the expression of uncertainty in measurement
  • JCGM 101:2008 — GUM Supplement 1: Propagation of distributions using a Monte Carlo method
  • NIST Technical Note 1297

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in

or with email

Forgot password?