Bolt Tightening Torque

Preload and tightening torque for ISO metric and UNC inch bolts by grade and nut factor.

How it works — Bolt Tightening Torque

T F d K

Inputs

d
Thread size
Sp
Property class
K
Nut factor K
%
Preload as % of proof load (%)

Formula

  • As = π/4 (d − k·p)², k = 0.9382 (ISO) / 0.9743 (UNC)
  • F = %·Sp·As
  • T = K·F·d

Results

T
Tightening torque
F
Target preload
As
Tensile stress area
Fp
Proof load

Dry steel ≈ 0.20, lubricated ≈ 0.15, anti-seize ≈ 0.12

Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

As = π/4 (d − k·p)², k = 0.9382 (ISO) / 0.9743 (UNC) · F = %·Sp·As · T = K·F·d

Torque–preload scatter with the nut-factor method is typically ±25 %. Follow the fastener manufacturer's data where available.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Short-form torque equation T = K·F·d; K lumps thread and under-head friction.
  • Coarse threads; proof stress from the property class or SAE grade.

References

  • R. G. Budynas, J. K. Nisbett, Shigley's Mechanical Engineering Design
  • VDI 2230 Part 1: Systematic calculation of highly stressed bolted joints
  • ISO 898-1 / SAE J429 — fastener proof loads

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in

or with email

Forgot password?