Bolt Tightening Torque
Preload and tightening torque for ISO metric and UNC inch bolts by grade and nut factor.
How it works — Bolt Tightening Torque
Inputs
- d
- Thread size
- Sp
- SAE grade
- K
- Nut factor K
- %
- Preload as % of proof load (%)
Formula
- As = π/4 (d − k·p)², k = 0.9382 (ISO) / 0.9743 (UNC)
- F = %·Sp·As
- T = K·F·d
Results
- T
- Tightening torque
- F
- Target preload
- As
- Tensile stress area
- Fp
- Proof load
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
As = π/4 (d − k·p)², k = 0.9382 (ISO) / 0.9743 (UNC) · F = %·Sp·As · T = K·F·d
Formulas are evaluated in SI units; inputs and results are converted.
Torque–preload scatter with the nut-factor method is typically ±25 %. Follow the fastener manufacturer's data where available.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Assumptions
- Short-form torque equation T = K·F·d; K lumps thread and under-head friction.
- Coarse threads; proof stress from the property class or SAE grade.
References
- R. G. Budynas, J. K. Nisbett, Shigley's Mechanical Engineering Design
- VDI 2230 Part 1: Systematic calculation of highly stressed bolted joints
- ISO 898-1 / SAE J429 — fastener proof loads
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Mechanical tools
- Mechanical Gear Ratio & Output Speed Ratio, output speed, torque and power of a simple gear pair. Open tool
- Mechanical Pipe Pressure Drop (Darcy–Weisbach) Friction pressure loss, velocity and Reynolds number for flow in a straight circular pipe. Open tool
- Mechanical Pump Head, Power & NPSH Total dynamic head, shaft and motor power, NPSH available and the system curve for a pumping line. Open tool
- Mechanical Heat Conduction Through a Wall Steady-state conductive heat flow, flux, RSI and U-value through a plane wall. Open tool