Bolted Joint Analysis

Preload, bolt and member stiffness, load sharing, and factors of safety against yielding, separation and slip for a group of bolts.

How it works — Bolted Joint Analysis

P P V V l Fi

Inputs

d
Thread size
n
Number of bolts
Fi
Preload as % of proof load (%)
l
Grip length (mm)
P
External tensile load (total) (kN)
V
External shear load (total) (kN)

Formula

  • C = k_b/(k_b + k_m)
  • F_b = F_i + C·P
  • n_0 = F_i / P(1 − C)

Results

Fb
Bolt load (preload + share of external load)
C
Joint stiffness constant C
np
Yielding factor of safety
n0
Joint separation factor of safety
Bolts
Joint
Loads

Clean mill scale ≈ 0.3, blast-cleaned ≈ 0.5

Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

C = k_b/(k_b + k_m) · F_b = F_i + C·P · n_0 = F_i / P(1 − C)

Separation factor below about 1.5 or a yielding factor below 1 is flagged. Threads are assumed to lie in the shear plane (conservative).

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Linear-elastic, homogeneous and isotropic material.
  • Concentric tensile load shared equally between the bolts; no prying action.
  • Member stiffness from a 30° pressure cone with both members of the same material (Shigley).
  • Threaded length in the grip taken as 2d + 6 mm.
  • Static loads: no dynamic amplification, fatigue or impact.

References

  • R. G. Budynas, J. K. Nisbett, Shigley's Mechanical Engineering Design
  • VDI 2230 Part 1: Systematic calculation of highly stressed bolted joints
  • ISO 898-1 / SAE J429 — fastener proof loads

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.