Composite Wall Heat Transfer

U-value, heat loss and the temperature at every interface of a multi-layer wall with inside and outside air films.

How it works — Composite Wall Heat Transfer

Ti To hi ho L1 L2 L3 q

Inputs

Ti
Inside air temperature (°C)
To
Outside air temperature (°C)
hi
Inside film coefficient h_i (W/m²·K)
ho
Outside film coefficient h_o (W/m²·K)
L1
Layer 1 thickness (mm)
k1
Layer 1 conductivity k (W/m·K)

Formula

  • R_T = 1/h_i + ΣL/k + 1/h_o
  • U = 1 / R_T
  • Q = U·A·ΔT

Results

U
U-value
q
Heat flux
Q
Heat flow
Conditions

Still indoor air ≈ 7.7 (R_si = 0.13); blank = ignore

Outdoor, moderate wind ≈ 25 (R_se = 0.04); blank = ignore

Layers (inside → outside)
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

R_T = 1/h_i + ΣLₙ/kₙ + 1/h_o · U = 1/R_T · Q = U·A·ΔT

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Steady state, one-dimensional heat flow.
  • Thermal conductivity constant with temperature.
  • Perfect contact between layers; no thermal bridges.
  • Radiation is not modelled separately; include it in the film coefficient if significant.

References

  • F. P. Incropera et al., Fundamentals of Heat and Mass Transfer
  • ASHRAE Handbook — Fundamentals
  • ISO 6946: Building components — Thermal resistance and thermal transmittance

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.