Water Hammer (Pressure Surge)
Pressure-wave speed, critical closure time and the surge pressure when a valve closes, for rigid and plastic pipes.
How it works — Water Hammer (Pressure Surge)
Inputs
- L
- Pipe length to the reservoir (m)
- Δv
- Velocity change (m/s)
- t
- Valve closure time (s)
Formula
- Δp = ρ·a·Δv
- t_c = 2L/a
Results
- a
- Wave speed
- Δp
- Pressure surge
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
a = √[(K/ρ)/(1 + KD/Ee)] · Δp = ρaΔv (t ≤ 2L/a) · Δp = 2ρLΔv/t
Closing more slowly than 2L/a strongly reduces the surge. Check the pipe and fittings against the steady pressure plus the surge.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Assumptions
- Elastic, thin-walled pipe anchored against axial movement; no cavitation or friction damping.
- Michaud's linear-closure formula for closures slower than 2L/a.
References
- E. B. Wylie, V. L. Streeter, Fluid Transients in Systems
- AWWA M11: Steel pipe design
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Mechanical tools
- Mechanical Gear Ratio & Output Speed Ratio, output speed, torque and power of a simple gear pair. Open tool
- Mechanical Bolt Tightening Torque Preload and tightening torque for ISO metric and UNC inch bolts by grade and nut factor. Open tool
- Mechanical Pipe Pressure Drop (Darcy–Weisbach) Friction pressure loss, velocity and Reynolds number for flow in a straight circular pipe. Open tool
- Mechanical Pump Head, Power & NPSH Total dynamic head, shaft and motor power, NPSH available and the system curve for a pumping line. Open tool