Occupant Load & Egress
Occupant load, number of exits, exit and stair widths and travel-distance limit for a floor area and occupancy (IBC-based, preliminary).
How it works — Occupant Load & Egress
Inputs
- A
- Floor area (m²)
- n
- Exits provided
- W
- Clear width of each exit door (mm)
Formula
- OL = A / load factor
- W = OL × 0.2 in
Results
- OL
- Occupant load
- n
- Required number of exits
- W
- Required clear door/corridor exit width
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
OL = area / load factor · W = OL × 0.2 in (0.3 in stairs)
Preliminary check only: requirements vary by jurisdiction and building classification; confirm with the governing code and authority.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Assumptions
- IBC 2021 Table 1004.5 load factors and §1005.3 capacity factors (not the reduced factors for sprinklered buildings with voice alarm).
- Exits are equally sized and remotely located; common path and dead-end limits are not checked.
References
- International Building Code 2021, §1004–1006, §1017 (preliminary)
- NFPA 101 Life Safety Code (comparable requirements)
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Architectural tools
- Architectural Shadow Cast & Sun Path Simulator Interactive 3D sun-path and shadow study: see where a building's shadow falls at any time of day on the solstices and equinoxes. Open tool
- Architectural Stair Calculator Riser count and height, tread run, stair angle and the 2R + T comfort rule from the total floor-to-floor rise. Open tool
- Architectural Roof Pitch Calculator Roof angle, pitch in 12, percent slope and rafter length from rise and run. Open tool
- Architectural Wall Area & Paint Calculator Paintable wall area and litres of paint for a rectangular room, net of doors and windows. Open tool