Level 3 — Standard / code based

Wind Velocity Pressure & Wall Pressures (ASCE 7)

Velocity pressure with exposure, topography, directionality and elevation factors, windward and leeward wall pressures and the lateral force on a building.

How it works — Wind Velocity Pressure & Wall Pressures (ASCE 7)

qz h G·C_p

Inputs

V
Basic wind speed V (m/s)
h
Mean roof height (m)

Formula

  • q_z = 0.613·K_zK_ztK_dK_eV²
  • K_z = 2.01(z/z_g)^(2/α)
  • p = qGC_p − q_h(GC_pi)

Results

qz
Velocity pressure at roof height q_h

−0.5 for L/B ≤ 1, −0.3 for 2, −0.2 for ≥ 4

Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

q_z = 0.613·K_zK_ztK_dK_eV² · K_z = 2.01(z/z_g)^(2/α) · p = qGC_p − q_h(GC_pi)

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 3 — Standard / code based

Follows the method of the named design standard within the stated scope; it does not check every provision of that standard.

Design standard / method: ASCE 7-16 Chapters 26–27: velocity pressure and MWFRS wall pressures (directional procedure, enclosed rectangular building)

Assumptions

  • Enclosed or partially enclosed rectangular building; roof pressures, components and cladding not included.

References

  • ASCE/SEI 7-16: Minimum Design Loads for Buildings and Other Structures

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.