Orifice, Nozzle & Venturi Flow Meter

Flow rate from the differential pressure across an orifice plate, flow nozzle or venturi, with the permanent pressure loss.

How it works — Orifice, Nozzle & Venturi Flow Meter

D d Δp Q

Inputs

D
Pipe inside diameter D (mm)
d
Bore / throat diameter d (mm)
Δp
Differential pressure Δp (kPa)

Formula

  • Q = C_d·E·(πd²/4)·√(2Δp/ρ)

Results

Q
Volume flow rate
β
Diameter ratio β
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

Q = C_d·E·(πd²/4)·√(2Δp/ρ) · E = 1/√(1 − β⁴)

For gases, multiply by the expansibility factor ε; β between 0.2 and 0.75 is the usual range.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Incompressible fluid, fully developed flow with enough straight pipe upstream.
  • Constant discharge coefficient (turbulent flow).

References

  • ISO 5167-1…4: Measurement of fluid flow by means of pressure differential devices
  • ASME MFC-3M

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.