Orifice, Nozzle & Venturi Flow Meter
Flow rate from the differential pressure across an orifice plate, flow nozzle or venturi, with the permanent pressure loss.
How it works — Orifice, Nozzle & Venturi Flow Meter
Inputs
- D
- Pipe inside diameter D (mm)
- d
- Bore / throat diameter d (mm)
- Δp
- Differential pressure Δp (kPa)
Formula
- Q = C_d·E·(πd²/4)·√(2Δp/ρ)
Results
- Q
- Volume flow rate
- β
- Diameter ratio β
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
Q = C_d·E·(πd²/4)·√(2Δp/ρ) · E = 1/√(1 − β⁴)
For gases, multiply by the expansibility factor ε; β between 0.2 and 0.75 is the usual range.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Assumptions
- Incompressible fluid, fully developed flow with enough straight pipe upstream.
- Constant discharge coefficient (turbulent flow).
References
- ISO 5167-1…4: Measurement of fluid flow by means of pressure differential devices
- ASME MFC-3M
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Mechanical tools
- Mechanical Gear Ratio & Output Speed Ratio, output speed, torque and power of a simple gear pair. Open tool
- Mechanical Bolt Tightening Torque Preload and tightening torque for ISO metric and UNC inch bolts by grade and nut factor. Open tool
- Mechanical Pipe Pressure Drop (Darcy–Weisbach) Friction pressure loss, velocity and Reynolds number for flow in a straight circular pipe. Open tool
- Mechanical Pump Head, Power & NPSH Total dynamic head, shaft and motor power, NPSH available and the system curve for a pumping line. Open tool