Level 2 — Engineering approximation

Induction Motor Equivalent Circuit & Torque–Speed Curve

Synchronous speed, slip, stator current, power flow, efficiency, starting and pull-out torque of a three-phase induction motor from its per-phase equivalent circuit.

How it works — Induction Motor Equivalent Circuit & Torque–Speed Curve

nm ns = 120f/p n T

Inputs

V
Line-to-line voltage (V)
f
Frequency (Hz)
p
Number of poles
s
Slip (%)
R2
Rotor resistance R₂ (referred) (Ω)

Formula

  • n_s = 120f/p
  • s = (n_s − n_m)/n_s
  • P_AG = 3I₂²R₂/s
  • τ = P_AG/ω_s
  • P_conv = (1 − s)P_AG

Results

ns
Synchronous speed
nm
Rotor speed
T
Induced torque
η
Efficiency
Supply
Operating point
Per-phase equivalent circuit
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

n_s = 120f/p · s = (n_s − n_m)/n_s · P_AG = 3I₂²R₂/s · τ = P_AG/ω_s · P_conv = (1 − s)P_AG

The default values reproduce Chapman's worked example of a 460 V, 25 hp, four-pole motor at 2.2 % slip.

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Calculation level & design standard

Level 2 — Engineering approximation

A preliminary engineering model with the simplifications listed under Assumptions.

Preliminary engineering calculation — no jurisdiction-specific code compliance claimed. Verify the applicable requirements with a qualified professional.

Assumptions

  • Wye-connected stator; per-phase T equivalent circuit with constant parameters (no saturation or deep-bar effect).
  • Core losses are lumped with the rotational losses.
  • Sinusoidal supply; three-phase loads are balanced.

References

  • S. J. Chapman, Electric Machinery Fundamentals
  • IEEE Std 112: Test procedure for polyphase induction motors and generators

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.

Sign in

or with email

Forgot password?