Weir Flow
Discharge over rectangular, V-notch and broad-crested weirs from the head, with a rating curve.
How it works — Weir Flow
Inputs
- H
- Head over the crest H (ft)
- b
- Crest width b (ft)
Formula
- Q = ⅔C_d√(2g)·b·H^1.5
Results
- Q
- Discharge
Inputs
Results
Enter your values and press Calculate. The defaults are a worked example.
Formula
Q = ⅔C_d√(2g)·b·H^1.5 · Q = 8/15·C_d√(2g)·tan(θ/2)·H^2.5
Formulas are evaluated in SI units; inputs and results are converted.
Show the math
Worked solution
Press Calculate to see every step with your values substituted.
Assumptions
- Free (unsubmerged) flow with a well-ventilated nappe; head measured upstream of drawdown.
References
- ISO 1438: Open channel flow measurement using thin-plate weirs
- V. T. Chow, Open-Channel Hydraulics
Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.
More Mechanical tools
- Mechanical Gear Ratio & Output Speed Ratio, output speed, torque and power of a simple gear pair. Open tool
- Mechanical Bolt Tightening Torque Preload and tightening torque for ISO metric and UNC inch bolts by grade and nut factor. Open tool
- Mechanical Pipe Pressure Drop (Darcy–Weisbach) Friction pressure loss, velocity and Reynolds number for flow in a straight circular pipe. Open tool
- Mechanical Pump Head, Power & NPSH Total dynamic head, shaft and motor power, NPSH available and the system curve for a pumping line. Open tool