Weir Flow

Discharge over rectangular, V-notch and broad-crested weirs from the head, with a rating curve.

How it works — Weir Flow

H Q

Inputs

H
Head over the crest H (m)
b
Crest width b (m)

Formula

  • Q = ⅔C_d√(2g)·b·H^1.5

Results

Q
Discharge
Reset

Results

Enter your values and press Calculate. The defaults are a worked example.

Formula

Q = ⅔C_d√(2g)·b·H^1.5 · Q = 8/15·C_d√(2g)·tan(θ/2)·H^2.5

Show the math

Worked solution

Press Calculate to see every step with your values substituted.

Assumptions

  • Free (unsubmerged) flow with a well-ventilated nappe; head measured upstream of drawdown.

References

  • ISO 1438: Open channel flow measurement using thin-plate weirs
  • V. T. Chow, Open-Channel Hydraulics

Results are for preliminary design and education. Verify against the governing code and have critical work checked by a licensed professional engineer.